name: Energy meter
# products:
#   - id: UNKNOWN
#     name: WDYK 4P100A
primary_entity:
  entity: sensor
  class: energy
  dps:
    - id: 1
      type: integer
      name: sensor
      unit: kWh
      class: total_increasing
      optional: true
      mapping:
        - scale: 100
    - id: 6
      name: phase_a
      type: base64
      optional: true
      force: true
    - id: 7
      name: phase_b
      type: base64
      optional: true
      force: true
    - id: 8
      name: phase_c
      type: base64
      optional: true
      force: true
    - id: 9
      type: bitfield
      name: fault_code
    - id: 19
      type: string
      name: breaker_number
    - id: 116
      type: string
      name: card_id
      optional: true
secondary_entities:
  - entity: binary_sensor
    name: Short circuit
    class: problem
    category: diagnostic
    dps:
      - id: 9
        type: bitfield
        name: sensor
        mapping:
          - dps_val: 1
            value: true
          - value: false
  - entity: binary_sensor
    name: Surge
    class: problem
    category: diagnostic
    dps:
      - id: 9
        type: bitfield
        name: sensor
        mapping:
          - dps_val: 2
            value: true
          - value: false
  - entity: binary_sensor
    name: Overload
    class: problem
    category: diagnostic
    dps:
      - id: 9
        type: bitfield
        name: sensor
        mapping:
          - dps_val: 4
            value: true
          - value: false
  - entity: binary_sensor
    name: Current leak
    class: safety
    category: diagnostic
    dps:
      - id: 9
        type: bitfield
        name: sensor
        mapping:
          - dps_val: 8
            value: true
          - value: false
  - entity: binary_sensor
    name: Overheat
    class: heat
    category: diagnostic
    dps:
      - id: 9
        type: bitfield
        name: sensor
        mapping:
          - dps_val: 16
            value: true
          - value: false
  - entity: binary_sensor
    name: Fire
    class: smoke
    category: diagnostic
    dps:
      - id: 9
        type: bitfield
        name: sensor
        mapping:
          - dps_val: 32
            value: true
          - value: false
  - entity: binary_sensor
    name: Over power
    class: problem
    category: diagnostic
    dps:
      - id: 9
        type: bitfield
        name: sensor
        mapping:
          - dps_val: 64
            value: true
          - value: false
  - entity: binary_sensor
    name: Self test
    class: running
    category: diagnostic
    dps:
      - id: 9
        type: bitfield
        name: sensor
        mapping:
          - dps_val: 128
            value: true
          - value: false
  - entity: binary_sensor
    name: Over current
    class: problem
    category: diagnostic
    dps:
      - id: 9
        type: bitfield
        name: sensor
        mapping:
          - dps_val: 256
            value: true
          - value: false
  - entity: binary_sensor
    name: Unbalanced
    class: problem
    category: diagnostic
    dps:
      - id: 9
        type: bitfield
        name: sensor
        mapping:
          - dps_val: 512
            value: true
          - value: false
  - entity: binary_sensor
    name: Over voltage
    class: problem
    category: diagnostic
    dps:
      - id: 9
        type: bitfield
        name: sensor
        mapping:
          - dps_val: 1024
            value: true
          - value: false
  - entity: binary_sensor
    name: Under voltage
    class: problem
    category: diagnostic
    dps:
      - id: 9
        type: bitfield
        name: sensor
        mapping:
          - dps_val: 2048
            value: true
          - value: false
  - entity: binary_sensor
    name: Out of phase
    class: problem
    category: diagnostic
    dps:
      - id: 9
        type: bitfield
        name: sensor
        mapping:
          - dps_val: 4096
            value: true
          - value: false
  - entity: binary_sensor
    name: Outage
    class: power
    category: diagnostic
    dps:
      - id: 9
        type: bitfield
        name: sensor
        mapping:
          - dps_val: 8192
            value: false
          - value: true
  - entity: binary_sensor
    name: Magnetism
    class: tamper
    category: diagnostic
    dps:
      - id: 9
        type: bitfield
        name: sensor
        mapping:
          - dps_val: 16384
            value: true
          - value: false
  - entity: binary_sensor
    name: Credit low
    class: problem
    icon: "mdi:cash"
    category: diagnostic
    dps:
      - id: 9
        type: bitfield
        name: sensor
        mapping:
          - dps_val: 32768
            value: true
          - value: false
  - entity: binary_sensor
    name: "No balance"
    class: problem
    category: diagnostic
    dps:
      - id: 9
        type: bitfield
        name: sensor
        mapping:
          - dps_val: 65536
            value: true
          - value: false
  - entity: switch
    name: Prepay
    category: config
    icon: "mdi:cash"
    dps:
      - id: 11
        type: boolean
        name: switch
  - entity: button
    name: Reset energy
    category: config
    class: restart
    dps:
      - id: 12
        type: boolean
        name: button
  - entity: sensor
    name: Energy balance
    class: energy_storage
    category: diagnostic
    dps:
      - id: 13
        type: integer
        name: sensor
        unit: kWh
        class: measurement
        mapping:
          - scale: 100
  - entity: number
    name: Charge energy
    category: config
    class: energy_storage
    icon: "mdi:cash"
    dps:
      - id: 14
        type: integer
        name: value
        unit: kWh
        optional: true
        range:
          min: 0
          max: 999999
        mapping:
          - scale: 100
  - entity: switch
    name: Circuit breaker
    icon: "mdi:fuse"
    category: config
    dps:
      - id: 16
        type: boolean
        name: switch
        optional: true
  - entity: sensor
    name: Voltage A
    class: voltage
    category: diagnostic
    dps:
      - id: 6
        type: base64
        name: sensor
        optional: true
        unit: V
        mapping:
          - mask: "FFFFFF0000000000000000"
            scale: 10
  - entity: sensor
    name: Current A
    class: current
    category: diagnostic
    dps:
      - id: 6
        type: base64
        name: sensor
        optional: true
        unit: A
        mapping:
          - mask: "000000FFFFFF0000000000"
            scale: 1000
  - entity: sensor
    name: Power A
    class: power
    category: diagnostic
    dps:
      - id: 6
        type: base64
        name: sensor
        optional: true
        unit: kW
        mapping:
          - mask: "000000000000FFFFFF0000"
            scale: 1000
  - entity: sensor
    name: Voltage B
    class: voltage
    category: diagnostic
    dps:
      - id: 7
        type: base64
        name: sensor
        optional: true
        unit: V
        mapping:
          - mask: "FFFFFF000000000000"
            scale: 10
  - entity: sensor
    name: Current B
    class: current
    category: diagnostic
    dps:
      - id: 7
        type: base64
        name: sensor
        optional: true
        unit: A
        mapping:
          - mask: "000000FFFFFF000000"
            scale: 1000
  - entity: sensor
    name: Power B
    class: power
    category: diagnostic
    dps:
      - id: 7
        type: base64
        name: sensor
        optional: true
        unit: kW
        mapping:
          - mask: "000000000000FFFFFF"
            scale: 1000
  - entity: sensor
    name: Voltage C
    class: voltage
    category: diagnostic
    dps:
      - id: 8
        type: base64
        name: sensor
        optional: true
        unit: V
        mapping:
          - mask: "FFFFFF000000000000"
            scale: 10
  - entity: sensor
    name: Current C
    class: current
    category: diagnostic
    dps:
      - id: 8
        type: base64
        name: sensor
        optional: true
        unit: A
        mapping:
          - mask: "000000FFFFFF000000"
            scale: 1000
  - entity: sensor
    name: Power C
    class: power
    category: diagnostic
    dps:
      - id: 8
        type: base64
        name: sensor
        optional: true
        unit: kW
        mapping:
          - mask: "000000000000FFFFFF"
            scale: 1000
  - entity: number
    name: Overvoltage threshold
    category: config
    class: voltage
    icon: "mdi:flash-alert"
    dps:
      - id: 101
        type: integer
        name: value
        unit: V
        range:
          min: 230
          max: 300
  - entity: number
    name: Undervoltage threshold
    category: config
    class: voltage
    icon: "mdi:flash-alert"
    dps:
      - id: 102
        type: integer
        name: value
        unit: V
        range:
          min: 90
          max: 210
  - entity: number
    name: Overcurrent threshold
    category: config
    class: current
    icon: "mdi:fuse-alert"
    dps:
      - id: 103
        type: integer
        name: value
        unit: A
        range:
          min: 1
          max: 63
  - entity: number
    name: Leakage current
    category: config
    class: current
    dps:
      - id: 104
        type: integer
        name: value
        unit: mA
        range:
          min: 10
          max: 100
  - entity: switch
    name: Mute alarm
    icon: "mdi:volume-mute"
    category: config
    dps:
      - id: 105
        type: boolean
        name: switch
  - entity: binary_sensor
    name: Earth leak
    class: safety
    category: diagnostic
    dps:
      - id: 106
        type: boolean
        name: sensor
  - entity: button
    name: Reset total energy
    class: restart
    category: config
    dps:
      - id: 115
        type: boolean
        name: button
        optional: true
  - entity: button
    name: Reset balance energy
    class: restart
    category: config
    dps:
      - id: 12
        type: boolean
        name: button