name: Power clamp meter
products:
  - id: nslr42tt
    name: PC321-Z-TY
primary_entity:
  entity: sensor
  class: energy
  dps:
    - id: 1
      type: integer
      name: sensor
      mapping:
        - scale: 100
      unit: kWh
      class: total_increasing
    - id: 3
      type: string
      name: monthly
      optional: true
    - id: 4
      type: string
      name: daily
      optional: true
secondary_entities:
  - entity: sensor
    category: diagnostic
    name: Voltage A
    class: voltage
    dps:
      - id: 6
        name: sensor
        type: base64
        unit: V
        optional: true
        mapping:
          - scale: 10
            mask: "FFFF000000000000"
  - entity: sensor
    category: diagnostic
    name: Current A
    class: current
    dps:
      - id: 6
        name: sensor
        type: base64
        unit: A
        optional: true
        mapping:
          - scale: 1000
            mask: "0000FFFFFF000000"
  - entity: sensor
    category: diagnostic
    name: Power A
    class: power
    dps:
      - id: 6
        name: sensor
        type: base64
        unit: kW
        optional: true
        mapping:
          - scale: 1000
            mask: "0000000000FFFFFF"
  - entity: sensor
    category: diagnostic
    name: Voltage B
    class: voltage
    dps:
      - id: 7
        name: sensor
        type: base64
        unit: V
        optional: true
        mapping:
          - scale: 10
            mask: "FFFF000000000000"
  - entity: sensor
    category: diagnostic
    name: Current B
    class: current
    dps:
      - id: 7
        name: sensor
        type: base64
        unit: A
        optional: true
        mapping:
          - scale: 1000
            mask: "0000FFFFFF000000"
  - entity: sensor
    category: diagnostic
    name: Power B
    class: power
    dps:
      - id: 7
        name: sensor
        type: base64
        unit: kW
        optional: true
        mapping:
          - scale: 1000
            mask: "0000000000FFFFFF"
  - entity: sensor
    category: diagnostic
    name: Voltage C
    class: voltage
    dps:
      - id: 8
        name: sensor
        type: base64
        unit: V
        optional: true
        mapping:
          - scale: 10
            mask: "FFFF000000000000"
  - entity: sensor
    category: diagnostic
    name: Current C
    class: current
    dps:
      - id: 8
        name: sensor
        type: base64
        unit: A
        optional: true
        mapping:
          - scale: 1000
            mask: "0000FFFFFF000000"
  - entity: sensor
    category: diagnostic
    name: Power C
    class: power
    dps:
      - id: 8
        name: sensor
        type: base64
        unit: kW
        optional: true
        mapping:
          - scale: 1000
            mask: "0000000000FFFFFF"
  - entity: sensor
    class: power
    category: diagnostic
    dps:
      - id: 9
        type: integer
        name: sensor
        unit: kW
        class: measurement
        mapping:
          - scale: 1000
  - entity: sensor
    category: diagnostic
    name: Energy A
    dps:
      - id: 101
        name: sensor
        type: integer
        unit: kWh
        mapping:
          - scale: 100
  - entity: sensor
    category: diagnostic
    class: power_factor
    name: Power factor A
    dps:
      - id: 102
        name: sensor
        type: integer
        class: measurement
        mapping:
          - scale: 100
  - entity: sensor
    category: diagnostic
    name: Energy B
    dps:
      - id: 111
        name: sensor
        type: integer
        unit: kWh
        mapping:
          - scale: 100
  - entity: sensor
    category: diagnostic
    class: power_factor
    name: Power factor B
    dps:
      - id: 112
        name: sensor
        type: integer
        class: measurement
        mapping:
          - scale: 100
  - entity: sensor
    category: diagnostic
    name: Energy C
    dps:
      - id: 121
        name: sensor
        type: integer
        unit: kWh
        mapping:
          - scale: 100
  - entity: sensor
    category: diagnostic
    class: power_factor
    name: Power factor C
    dps:
      - id: 122
        name: sensor
        type: integer
        class: measurement
        mapping:
          - scale: 100
  - entity: sensor
    category: diagnostic
    class: current
    dps:
      - id: 131
        type: integer
        name: sensor
        unit: A
        class: measurement
        force: true
        mapping:
          - scale: 1000
  - entity: sensor
    category: diagnostic
    class: frequency
    dps:
      - id: 132
        type: integer
        name: sensor
        unit: Hz
        class: measurement
  - entity: sensor
    category: diagnostic
    class: temperature
    dps:
      - id: 133
        type: integer
        name: sensor
        unit: C
        class: measurement
        mapping:
          - scale: 10
  - entity: binary_sensor
    class: problem
    category: diagnostic
    dps:
      - id: 134
        type: bitfield
        name: sensor
        mapping:
          - dps_val: 0
            value: false
          - value: true
      - id: 134
        type: bitfield
        name: fault_code