name: Bidirectional energy meter
products:
  - id: z95s7p3z54xbsjnl
    name: MatSee Plus bidirectional 2 channel clamp meter
  - id: bbcg1hrkrj5rifsd
    name: MatSee Plus bidirectional 2 channel clamp meter
primary_entity:
  entity: sensor
  name: Energy consumed
  class: energy
  dps:
    - id: 1
      type: integer
      optional: true
      name: sensor
      unit: kWh
      class: total_increasing
      mapping:
        - dps_val: null
          value_redirect: alternate
        - scale: 100
    - id: 130
      type: integer
      optional: true
      name: alternate
      hidden: true
      mapping:
        - scale: 100
secondary_entities:
  - entity: sensor
    name: Energy produced
    class: energy
    dps:
      - id: 2
        type: integer
        optional: true
        name: sensor
        unit: kWh
        class: total_increasing
        mapping:
          - dps_val: null
            value_redirect: alternate
          - scale: 100
      - id: 131
        type: integer
        optional: true
        name: alternate
        hidden: true
        mapping:
          - scale: 100
  - entity: sensor
    name: Power A
    class: power
    category: diagnostic
    dps:
      - id: 101
        type: integer
        name: sensor
        unit: W
        class: measurement
        mapping:
          - scale: 10
      - id: 102
        type: string
        optional: true
        name: direction
      - id: 118
        type: integer
        name: calibration
        mapping:
          - scale: 1000
  - entity: sensor
    name: Power B
    class: power
    category: diagnostic
    dps:
      - id: 105
        type: integer
        name: sensor
        unit: W
        class: measurement
        mapping:
          - scale: 10
      - id: 104
        type: string
        optional: true
        name: direction
      - id: 124
        type: integer
        name: calibration
        mapping:
          - scale: 1000
  - entity: sensor
    name: Energy consumed A
    class: energy
    category: diagnostic
    dps:
      - id: 106
        type: integer
        name: sensor
        unit: kWh
        class: total_increasing
        mapping:
          - scale: 100
      - id: 119
        type: integer
        name: calibration
        mapping:
          - scale: 1000
  - entity: sensor
    name: Energy produced A
    class: energy
    category: diagnostic
    dps:
      - id: 107
        type: integer
        name: sensor
        unit: kWh
        class: total_increasing
        mapping:
          - scale: 100
      - id: 127
        type: integer
        name: calibration
        mapping:
          - scale: 1000
  - entity: sensor
    name: Energy consumed B
    class: energy
    category: diagnostic
    dps:
      - id: 108
        type: integer
        name: sensor
        unit: kWh
        class: total_increasing
        mapping:
          - scale: 100
      - id: 125
        type: integer
        name: calibration
        mapping:
          - scale: 1000
  - entity: sensor
    name: Energy produced B
    class: energy
    category: diagnostic
    dps:
      - id: 109
        type: integer
        name: sensor
        unit: kWh
        class: total_increasing
        mapping:
          - scale: 100
      - id: 128
        type: integer
        name: calibration
        mapping:
          - scale: 1000
  - entity: sensor
    name: Power factor A
    class: power_factor
    category: diagnostic
    dps:
      - id: 110
        type: integer
        name: sensor
        unit: "%"
        class: measurement
  - entity: sensor
    class: frequency
    category: diagnostic
    dps:
      - id: 111
        type: integer
        name: sensor
        unit: Hz
        class: measurement
        mapping:
          - scale: 100
      - id: 122
        type: integer
        name: calibration
        mapping:
          - scale: 1000
  - entity: sensor
    class: voltage
    category: diagnostic
    dps:
      - id: 112
        type: integer
        name: sensor
        unit: V
        class: measurement
        mapping:
          - scale: 10
      - id: 116
        type: integer
        name: calibration
        mapping:
          - scale: 1000
  - entity: sensor
    name: Current A
    class: current
    category: diagnostic
    dps:
      - id: 113
        type: integer
        name: sensor
        unit: A
        class: measurement
        mapping:
          - scale: 1000
      - id: 117
        type: integer
        name: calibration
        mapping:
          - scale: 1000
  - entity: sensor
    name: Current B
    class: current
    category: diagnostic
    dps:
      - id: 114
        type: integer
        name: sensor
        unit: A
        class: measurement
        mapping:
          - scale: 1000
      - id: 123
        type: integer
        name: calibration
        mapping:
          - scale: 1000
  - entity: sensor
    name: Total power
    class: power
    category: diagnostic
    dps:
      - id: 115
        type: integer
        name: sensor
        unit: W
        class: measurement
        mapping:
          - scale: 10
  - entity: sensor
    name: Power factor B
    class: power_factor
    category: diagnostic
    dps:
      - id: 121
        type: integer
        name: sensor
        unit: "%"
        class: measurement
        mapping:
          - scale: 100
  - entity: number
    name: Reporting rate
    category: config
    icon: "mdi:timer-refresh"
    dps:
      - id: 129
        type: integer
        name: value
        unit: s
        range: