name: Hot water
products:
  - id: p2gjmmancu4t4ceg
    name: Hydrotherm Dynamic X8 gen 6
primary_entity:
  entity: water_heater
  dps:
    - id: 1
      type: boolean
      name: operation_mode
      mapping:
        - dps_val: false
          value: "off"
        - dps_val: true
          constraint: mode
          conditions:
            - dps_val: Stand
              value: heat_pump
            - dps_val: ECO
              value: eco
            - dps_val: HYB
              value: high_demand
            - dps_val: HYB1
              value: performance
            - dps_val: ELE
              value: electric
    - id: 2
      type: string
      name: mode
      hidden: true
    - id: 4
      type: integer
      name: temperature
      range:
        min: 15
        max: 75
      unit: C
    - id: 16
      type: integer
      optional: true
      name: current_temperature
      mapping:
        - dps_val: null
          value_redirect: inlet_temp
    - id: 21
      type: integer
      name: inlet_temp
    - id: 7
      type: boolean
      name: away_mode
    - id: 14
      type: integer
      name: eev
    - id: 40
      type: integer
      name: model_number
    - id: 108
      type: boolean
      name: dip_switch_1
    - id: 109
      type: boolean
      name: dip_switch_2
secondary_entities:
  - entity: binary_sensor
    class: problem
    category: diagnostic
    dps:
      - id: 15
        type: bitfield
        name: sensor
        mapping:
          - dps_val: 0
            value: false
          - value: true
      - id: 15
        type: bitfield
        name: fault_code
  - entity: binary_sensor
    class: running
    category: diagnostic
    dps:
      - id: 17
        type: string
        name: sensor
        mapping:
          - dps_val: normal
            value: true
          - value: false
      - id: 17
        type: string
        name: work_state
  - entity: sensor
    name: Energy today
    class: energy
    category: diagnostic
    dps:
      - id: 18
        type: integer
        name: sensor
        unit: kWh
        class: total_increasing
        mapping:
          - scale: 100
  - entity: sensor
    name: Flow
    class: enum
    icon: "mdi:waves-arrow-right"
    category: diagnostic
    dps:
      - id: 19
        type: string
        name: sensor
        mapping:
          - dps_val: "OFF"
            value: "Off"
          - dps_val: LOW
            value: Low
          - dps_val: High
            value: High
  - entity: sensor
    name: Return air temperature
    class: temperature
    category: diagnostic
    dps:
      - id: 20
        type: integer
        name: sensor
        unit: C
        class: measurement
  - entity: sensor
    name: Inlet temperature
    class: temperature
    category: diagnostic
    dps:
      - id: 21
        type: integer
        name: sensor
        unit: C
        class: measurement
  - entity: sensor
    name: Outlet temperature
    class: temperature
    category: diagnostic
    dps:
      - id: 22
        type: integer
        name: sensor
        unit: C
        class: measurement
  - entity: sensor
    name: Coil temperature
    class: temperature
    category: diagnostic
    dps:
      - id: 23
        type: integer
        name: sensor
        unit: C
        class: measurement
  - entity: sensor
    name: Exhaust temperature
    class: temperature
    category: diagnostic
    dps:
      - id: 24
        type: integer
        name: sensor
        unit: C
        class: measurement
  - entity: sensor
    class: temperature
    dps:
      - id: 26
        type: integer
        name: sensor
        unit: C
        class: measurement
  - entity: binary_sensor
    name: Compressor
    class: running
    category: diagnostic
    dps:
      - id: 27
        type: boolean
        name: sensor
  - entity: binary_sensor
    name: Four-way valve
    class: opening
    category: diagnostic
    dps:
      - id: 28
        type: boolean
        name: sensor
  - entity: binary_sensor
    name: Low pressure valve
    class: opening
    category: diagnostic
    dps:
      - id: 29
        type: boolean
        name: sensor
  - entity: binary_sensor
    name: Fluoride cycle
    class: running
    category: diagnostic
    dps:
      - id: 30
        type: boolean
        name: sensor
  - entity: binary_sensor
    name: Pump
    class: running
    category: diagnostic
    dps:
      - id: 31
        type: boolean
        name: sensor
  - entity: binary_sensor
    name: Element
    class: running
    category: diagnostic
    dps:
      - id: 32
        type: boolean
        name: sensor
  - entity: binary_sensor
    translation_key: defrost
    category: diagnostic
    dps:
      - id: 33
        type: boolean
        name: sensor
      - id: 41
        type: integer
        name: minutes_until
  - entity: sensor
    class: current
    category: diagnostic
    dps:
      - id: 101
        type: integer
        name: sensor
        unit: A
        class: measurement
        mapping:
          - scale: 1000
  - entity: sensor
    class: voltage
    category: diagnostic
    dps:
      - id: 102
        type: integer
        name: sensor
        unit: V
        class: measurement
        mapping:
          - scale: 10
  - entity: sensor
    class: power
    category: diagnostic
    dps:
      - id: 103
        type: integer
        name: sensor
        unit: W
        class: measurement
        mapping:
          - scale: 10
  - entity: sensor
    class: energy
    category: diagnostic
    dps:
      - id: 104
        type: integer
        name: sensor
        unit: kWh
        class: total_increasing
        mapping:
          - scale: 100
  - entity: binary_sensor
    class: power
    category: diagnostic
    dps:
      - id: 105
        type: boolean
        name: sensor
  - entity: binary_sensor
    class: connectivity
    category: diagnostic
    dps:
      - id: 106
        type: boolean
        name: sensor
  - entity: binary_sensor
    name: Water flow
    class: moving
    category: diagnostic
    dps:
      - id: 107
        type: boolean
        name: sensor