name: Dual energy meter
products:
  - id: jbarpbsikxovmxeg
    name: Bidirectional 2-way CT clamp
primary_entity:
  entity: sensor
  class: energy
  name: Total active energy
  category: diagnostic
  dps:
    - id: 107
      type: integer
      name: sensor
      unit: kWh
      class: total_increasing
      mapping:
        - scale: 100
secondary_entities:
  - entity: sensor
    class: power
    category: diagnostic
    dps:
      - id: 19
        type: integer
        name: sensor
        unit: W
        class: measurement
        mapping:
          - scale: 10
      - id: 103
        type: integer
        name: apparent_power
        mapping:
          - scale: 10
      - id: 104
        type: integer
        name: current_power
        mapping:
          - scale: 10
      - id: 126
        type: integer
        name: calibration_a
      - id: 131
        type: integer
        name: calibration_b
  - entity: sensor
    class: voltage
    category: diagnostic
    dps:
      - id: 20
        type: integer
        name: sensor
        unit: V
        class: measurement
        mapping:
          - scale: 10
      - id: 123
        type: integer
        name: calibration
  - entity: sensor
    class: current
    category: diagnostic
    dps:
      - id: 101
        type: integer
        name: sensor
        unit: A
        class: measurement
        mapping:
          - scale: 1000
      - id: 102
        type: integer
        name: maximum
        mapping:
          - scale: 1000
      - id: 125
        type: integer
        name: calibration_a
      - id: 130
        type: integer
        name: calibration_b
  - entity: sensor
    class: frequency
    category: diagnostic
    dps:
      - id: 105
        type: integer
        name: sensor
        unit: Hz
        class: measurement
        mapping:
          - scale: 100
      - id: 124
        type: integer
        name: calibration
  - entity: sensor
    class: energy
    name: Total forward energy
    category: diagnostic
    dps:
      - id: 110
        type: integer
        name: sensor
        unit: kWh
        class: total_increasing
        mapping:
          - scale: 100
      - id: 115
        type: integer
        name: channel_a
        mapping:
          - scale: 100
      - id: 117
        type: integer
        name: channel_b
        mapping:
          - scale: 100
  - entity: sensor
    name: Forward energy A
    class: energy
    category: diagnostic
    dps:
      - id: 115
        type: integer
        name: sensor
        unit: kWh
        class: total_increasing
        mapping:
          - scale: 100
      - id: 127
        type: integer
        name: calibration
  - entity: sensor
    name: Reverse energy A
    class: energy
    category: diagnostic
    dps:
      - id: 116
        type: integer
        name: sensor
        unit: kWh
        class: total_increasing
        mapping:
          - scale: 100
      - id: 128
        type: integer
        name: calibration
  - entity: sensor
    name: Forward energy B
    class: energy
    category: diagnostic
    dps:
      - id: 117
        type: integer
        name: sensor
        unit: kWh
        class: total_increasing
        mapping:
          - scale: 100
      - id: 132
        type: integer
        name: calibration
  - entity: sensor
    name: Reverse energy B
    class: energy
    category: diagnostic
    dps:
      - id: 118
        type: integer
        name: sensor
        unit: kWh
        class: total_increasing
        mapping:
          - scale: 100
      - id: 133
        type: integer
        name: calibration
  - entity: sensor
    name: Power factor A
    class: power_factor
    category: diagnostic
    dps:
      - id: 120
        type: integer
        name: sensor
        unit: "%"
        class: measurement
        mapping:
          - scale: 100
  - entity: sensor
    name: Power factor B
    class: power_factor
    category: diagnostic
    dps:
      - id: 121
        type: integer
        name: sensor
        unit: "%"
        class: measurement
        mapping:
          - scale: 100
  - entity: number
    name: Reporting frequency
    category: config
    icon: "mdi:timer-cog"
    dps:
      - id: 122
        type: integer
        name: value
        unit: s
        range:
          min: 3
          max: 60
  - entity: select
    name: Channel B select
    icon: "mdi:toggle-switch"
    category: config
    dps:
      - id: 140
        type: string
        optional: true
        name: option
        mapping:
          - dps_val: "0"
            value: "0"
          - dps_val: "1"
            value: "1"
  - entity: sensor
    name: Current direction A
    class: enum
    category: diagnostic
    dps:
      - id: 141
        type: integer
        name: sensor
        mapping:
          - dps_val: "0"
            value: forward
          - dps_val: "1"
            value: reverse
  - entity: sensor
    name: Current direction B
    class: enum
    category: diagnostic
    dps:
      - id: 142
        type: integer
        name: sensor
        mapping:
          - dps_val: "0"
            value: forward
          - dps_val: "1"
            value: reverse
  - entity: number
    name: Current overload limit A
    category: config
    class: current
    dps:
      - id: 143
        type: integer
        name: value
        unit: A
        range:
          min: 1
          max: 100
  - entity: number
    name: Current overload limit B
    category: config
    class: current
    dps:
      - id: 144
        type: integer
        name: value
        unit: A
        range:
          min: 1
          max: 100
  - entity: switch
    name: Current overload alarm A
    category: config
    icon: "mdi:fuse-alert"
    dps:
      - id: 145
        type: boolean
        name: switch
  - entity: switch
    name: Current overload alarm B
    category: config
    icon: "mdi:fuse-alert"
    dps:
      - id: 146
        type: boolean
        name: switch
  - entity: binary_sensor
    name: Current overload A
    class: problem
    category: diagnostic
    dps:
      - id: 147
        type: boolean
        name: sensor
  - entity: binary_sensor
    name: Current overload B
    class: problem
    category: diagnostic
    dps:
      - id: 148
        type: boolean
        name: sensor