name: Circuit breaker
products:
  - id: bryydwbntbjkq8pk
    name: Faens FSZN03-100AP 2P
primary_entity:
  entity: switch
  icon: "mdi:fuse"
  dps:
    - id: 1
      type: boolean
      name: switch
    - id: 101
      type: string
      name: event
    - id: 110
      type: string
      optional: true
      name: version
secondary_entities:
  - entity: sensor
    class: voltage
    category: diagnostic
    dps:
      - id: 22
        type: integer
        name: sensor
        unit: V
        class: measurement
        mapping:
          - scale: 10
      - id: 25
        type: integer
        name: calibration
  - entity: number
    name: Overvoltage threshold
    category: config
    icon: "mdi:arrow-collapse-up"
    dps:
      - id: 102
        type: integer
        name: value
        unit: "%"
        range:
          min: 110
          max: 200
  - entity: number
    name: Undervoltage threshold
    category: config
    icon: "mdi:arrow-collapse-down"
    dps:
      - id: 103
        type: integer
        name: value
        unit: "%"
        range:
          min: 50
          max: 90
  - entity: number
    name: Rated voltage
    class: voltage
    category: config
    dps:
      - id: 104
        type: integer
        name: value
        unit: V
        range:
          min: 150
          max: 300
  - entity: select
    name: Overvoltage action
    category: config
    dps:
      - id: 105
        type: string
        name: option
        mapping:
          - dps_val: Shut
            value: Remain closed
            icon: "mdi:electric-switch-closed"
          - dps_val: Alarm
            value: Alarm
            icon: "mdi:bell-alert"
          - dps_val: Trip
            value: Trip
            icon: "mdi:electric-switch"
  - entity: select
    name: Undervoltage action
    category: config
    dps:
      - id: 106
        type: string
        name: option
        mapping:
          - dps_val: Shut
            value: Remain closed
            icon: "mdi:electric-switch-closed"
          - dps_val: Alarm
            value: Alarm
            icon: "mdi:bell-alert"
          - dps_val: Trip
            value: Trip
            icon: "mdi:electric-switch"
  - entity: number
    name: Overvoltage delay
    category: config
    icon: "mdi:camera-timer"
    dps:
      - id: 107
        type: integer
        name: value
        unit: s
        range:
          min: 100
          max: 10000
        mapping:
          - step: 100
            scale: 1000
  - entity: number
    name: Undervoltage delay
    category: config
    icon: "mdi:camera-timer"
    dps:
      - id: 108
        type: integer
        name: value
        unit: s
        range:
          min: 1
          max: 10
  - entity: switch
    name: Auto reset
    category: config
    icon: "mdi:refresh-auto"
    dps:
      - id: 109
        type: boolean
        name: switch