name: Thermostat
products:
  - id: 7jzdtn4pwujmtskd
    name: Beca BAC-006 fancoil
primary_entity:
  entity: climate
  dps:
    - id: 1
      type: boolean
      name: hvac_mode
      mapping:
        - dps_val: false
          value: "off"
        - dps_val: true
          constraint: mode
          conditions:
            - dps_val: "cold"
              value: cool
            - dps_val: "hot"
              value: heat
            - dps_val: "wind"
              value: fan_only
    - id: 2
      type: string
      name: mode
      optional: true
      hidden: true
    - id: 4
      type: boolean
      name: preset_mode
      mapping:
        - dps_val: true
          value: "eco"
        - dps_val: false
          value: "none"
    - id: 16
      type: integer
      name: temperature
      unit: C
      range:
        min: 50
        max: 350
      mapping:
        - scale: 10
          step: 5
    - id: 19
      type: integer
      name: max_temperature
      mapping:
        - scale: 10
    - id: 26
      type: integer
      name: min_temperature
      mapping:
        - scale: 10
    - id: 24
      type: integer
      name: current_temperature
      mapping:
        - scale: 10
    - id: 36
      type: string
      name: hvac_action
      readonly: true
      mapping:
        - dps_val: close
          constraint: hvac_mode
          conditions:
            - dps_val: false
              value: "off"
            - dps_val: true
              value: idle
        - dps_val: open
          constraint: mode
          conditions:
            - dps_val: hot
              value: heating
            - dps_val: cold
              value: cooling
            - dps_val: wind
              value: fan
    - id: 28
      type: string
      name: fan_mode
      mapping:
        - dps_val: auto
          value: auto
        - dps_val: low
          value: low
        - dps_val: middle
          value: medium
        - dps_val: high
          value: high
secondary_entities:
  - entity: lock
    translation_key: child_lock
    category: config
    dps:
      - id: 40
        type: boolean
        name: lock
  - entity: number
    name: Temperature calibration
    icon: "mdi:thermometer-check"
    category: config
    dps:
      - id: 27
        name: value
        type: integer
        range:
          min: -9
          max: 9
  - entity: number
    name: Temperature hysteresis
    icon: "mdi:thermometer-plus"
    category: config
    dps:
      - id: 103
        type: integer
        name: value
        range:
          min: 1
          max: 5
  - entity: number
    name: ECO cool temperature
    category: config
    class: temperature
    icon: "mdi:thermometer-chevron-down"
    dps:
      - id: 104
        type: integer
        name: value
        range:
          min: 100
          max: 300
        mapping:
          - scale: 10
            step: 10
  - entity: number
    name: ECO heat temperature
    category: config
    class: temperature
    icon: "mdi:thermometer-chevron-up"
    dps:
      - id: 105
        type: integer
        name: value
        range:
          min: 100
          max: 300
        mapping:
          - scale: 10
            step: 10
  - entity: binary_sensor
    name: Schedule/Manual
    icon: "mdi:home-clock-outline"
    category: diagnostic
    dps:
      - id: 101
        type: boolean
        name: sensor
  - entity: binary_sensor
    name: Fan control
    icon: "mdi:fan"
    category: diagnostic
    dps:
      - id: 102
        type: boolean
        name: sensor